Vis enkel innførsel

dc.contributor.authorWahid, Radziah
dc.contributor.authorMulat, Daniel Girma
dc.contributor.authorGaby, John Christian
dc.contributor.authorHorn, Svein Jarle
dc.date.accessioned2020-11-09T15:14:02Z
dc.date.available2020-11-09T15:14:02Z
dc.date.created2019-05-13T12:29:52Z
dc.date.issued2019
dc.identifier.citationBiotechnology for Biofuels. 2019, 12 (104), 1-15.en_US
dc.identifier.issn1754-6834
dc.identifier.urihttps://hdl.handle.net/11250/2686982
dc.description.abstractBackground: Commercial biogas upgrading facilities are expensive and consume energy. Biological biogas upgrading may serve as a low-cost approach because it can be easily integrated with existing facilities at biogas plants. The microbial communities found in anaerobic digesters typically contain hydrogenotrophic methanogens, which can use hydrogen (H2) as a reducing agent for conversion of carbon dioxide (CO2) into methane (CH4). Thus, biological biogas upgrading through the exogenous addition of H2 into biogas digesters for the conversion of CO2 into CH4 can increase CH4 yield and lower CO2 emission. Results: The addition of 4 mol of H2 per mol of CO2 was optimal for batch biogas reactors and increased the CH4 content of the biogas from 67 to 94%. The CO2 content of the biogas was reduced from 33 to 3% and the average residual H2 content was 3%. At molar H2:CO2 ratios > 4:1, all CO2 was converted into CH4, but the pH increased above 8 due to depletion of CO2, which negatively influenced the process stability. Additionally, high residual H2 content in these reactors was unfavourable, causing volatile fatty acid accumulation and reduced CH4 yields. The reactor microbial communities shifted in composition over time, which corresponded to changes in the reactor variables. Numerous taxa responded to the H2 inputs, and in particular the hydrogenotrophic methanogen Methanobacterium increased in abundance with addition of H2. In addition, the apparent rapid response of hydrogenotrophic methanogens to intermittent H2 feeding indicates the suitability of biological methanation for variable H2 inputs, aligning well with fluctuations in renewable electricity production that may be used to produce H2. Conclusions: Our research demonstrates that the H2:CO2 ratio has a significant effect on reactor performance during in situ biological methanation. Consequently, the H2:CO2 molar ratio should be kept at 4:1 to avoid process instability. A shift toward hydrogenotrophic methanogenesis was indicated by an increase in the abundance of the obligate hydrogenotrophic methanogen Methanobacterium.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectBiogass oppgraderingen_US
dc.subjectBiogas upgradingen_US
dc.titleEffects of H2:CO2 ratio and H2 supply fluctuation on methane content and microbial community composition during in-situ biological biogas upgradingen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.pagenumber1-15en_US
dc.source.volume12en_US
dc.source.journalBiotechnology for Biofuelsen_US
dc.source.issue104en_US
dc.identifier.doi10.1186/s13068-019-1443-6
dc.identifier.cristin1697374
dc.relation.projectNorges forskningsråd: 257622en_US
cristin.unitcode192,12,0,0
cristin.unitnameKjemi, bioteknologi og matvitenskap
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal