Vis enkel innførsel

dc.contributor.authorEregno, Fasil Ejigu
dc.date.accessioned2014-02-18T10:38:37Z
dc.date.available2014-02-18T10:38:37Z
dc.date.copyright2013
dc.date.issued2014-02-18
dc.identifier.urihttp://hdl.handle.net/11250/189167
dc.descriptionLinear regression model is used to relate the physico-chemical parameters with microbial load of drinking water sourceno_NO
dc.description.abstractThe application of integrated study of water quality and statistics for environmental modelling is considered as a powerful analytical tool that has been thrived significantly during recent years. The present study was conducted to identify the significant physico-chemical factors that affects the raw water quality, and to study statistical interrelationships amongst them. Multiple linear regression models were developed to estimate microbial load in the raw water source, using data from the NRV drinking water treatment plant published from 1999 to 2012 and also from Norwegian school of veterinary science through VISK project. The study was conducted based on indicator microbial load which contain Total viable count "Kimtall", Coliform bacteria, Escherichia coli, Clostridium perfringens, and Intestinal Enterococci. In addition, microbial pathogen load of Noro virus, and Adeno virus were also incorporated. The explanatory variables examined for regression analysis were monitored properties of raw water and hyro-climatic data from the catchment which include; river discharge, raw water temperature, rainfall, pH, turbidity, conductivity, colour, and total organic carbon. Each indicator and pathogenic microbial loads have its own unique set of selected explanatory variables. The statistical significance tests were applied to the coefficients of the multiple linear regression models, and they are found to be significant. The regression equations were evaluated using measures of variability, including adjusted R2, which ranges from 38.0 % for Adeno virus concentration to 50.0 % for Ecoli concentration. The results revealed that the regression analysis provide useful mean for rapid monitoring of microbial raw water quality based on the physico-chemical parameters.no_NO
dc.description.sponsorshipThis work was sponsored by VISK projectno_NO
dc.language.isoengno_NO
dc.publisherNorwegian University of Life Sciences, Ås
dc.subjectGlomma Riverno_NO
dc.subjectmicrobial loadno_NO
dc.subjectMicrobial water qualityno_NO
dc.subjectRegression modellingno_NO
dc.titleMultiple linear regression models for estimating microbial load in a drinking water source case from the Glomma river, Norwayno_NO
dc.typeMaster thesisno_NO
dc.subject.nsiVDP::Mathematics and natural science: 400::Basic biosciences: 470::General microbiology: 472no_NO
dc.source.pagenumber35no_NO
dc.relation.projectVISK projectno_NO


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel