dc.description.abstractEndring av fargetall i Farris og befolkningsvekst i Vestfold har ført til at Vestfold Vann IKS må oppgradere renseanlegget sitt på Seierstad. I den anledning har Vestfold Vann bygget to pilotanlegg, der de skal sammenligne to ulike renseprosesser. Det ene pilotanlegget fokuserer på en UF-membran, og det andre er Moldeprosessen. Denne oppgaven omhandler driftsoptimalisering av Moldeprosessen, med råvann fra Farris. I denne oppgaven blir det sett på optimal koagulantdosering, optimal filterhastighet, og optimalisering av modning. Videre har det også blitt sett på modningstid og trykktap, for å se hvor lange filtersykluser som kan oppnås. Koagulanten som er brukt under forsøksperioden er PIX-318. Det er også blitt analysert prøvevann etter filter med ulike koagulantdoseringer og filterhastigheter, der parametere som fargetall, turbiditet, kalsiuminnhold, koagulerings-pH, pH etter filter, restjern og ledningsevner er testet. Her er det blitt testet koagulantdoseringer fra 2,0 mg Fe/l og opp til 4,2 mg Fe/l. Filterhastigheten har variert fra 4 m/h opp til 10 m/h. Resultater fra de tre fasene som er blitt kjørt i denne perioden har resultert i en anbefalt koagulantdosering på 4,2 mg Fe/l, med dobbel mengde under modning. Filterhastighet på 8 m/h ga tilfredsstillende resultater samtidig som at produksjonen av rentvann holdes på et høyt nivå. Tester av parameterne med koagulantdosering på 4,2 mg Fe/l ga tilfredsstillende resultater, da alle var innenfor drikkevannsforskriften og mattilsynets krav og erfaringer ved koaguleringsanlegg, bortsett fra kalsium-innholdet, som ligger litt under anbefalt minstegrense.en_US
dc.description.abstractChanges in color in Farris and population growth in Vestfold have led to Vestfold Vann IKS having to upgrade its treatment plant at Seierstad. On this occasion, Vestfold Vann has built two pilot plants, where they will compare two different treatment processes. One pilot plant focuses on a UF membrane, and the other is the Moldeprosess. This master thesis addresses operational optimization of the Moldeprosess, with raw water from Farris. Here, optimal coagulant dosing, optimal filter velocity, and optimization of maturation have been considered. Maturation time and pressure loss have been looked at to see how long filter cycles can be achieved. The coagulant used during the period is PIX-318. Sample water by filter with different coagulant dosages and filter rates has also been analyzed, where parameters such as color, turbidity, calcium content, coagulant pH, pH after filter, residual iron and conductivities have been tested. The coagulant dosages were from 2.0 mg Fe/l and up to 4.2 mg Fe/l. The filter velocity has varied from 4 m/h up to 10 m/h. Results from the three test periods that have been run during this period have resulted in a recommended coagulant dose of 4.2 mg Fe/l, with double the amount during maturation. Filter velocity of 8 m/h gave satisfactory results while keeping the production of clean water at a high level. Tests of the parameters with a coagulant dosage of 4.2 mg Fe/l gave satisfactory results, as all were within the drinking water regulations and the Norwegian Food Safety Authority's requirements and experience at coagulation plants, except for the calcium content, which is slightly below the recommended minimum limit.en_US
dc.language.isonoben_US
dc.publisherNorwegian University of Life Sciences, Åsen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.subjectFarrisen_US
dc.subjectDrikkevannen_US
dc.subjectDrinking wateren_US
dc.titlePilotforsøk med Moldeprosessen på råvann fra Farris : kartlegging av optimale koaguleringsbetingelser og filterhastigheten_US
dc.title.alternativePilot-scale investigation with Moldeprosessen : identifying optimal coagulation conditions and filter velocityen_US
dc.typeMaster thesisen_US